logo
Shenzhen Zhong Jian South Environment Co., Ltd.
Shenzhen Zhong Jian South Environment Co., Ltd.
produits
Zu Hause /

produits

Laminar Flow chamber Clean room Air Purification Equipment with 110V 220V voltage

Einzelheiten zum Produkt

Herkunftsort: China

Markenname: ZJNF

Zertifizierung: CE

Modellnummer: ZJ

Zahlungs- und Versandbedingungen

Min Bestellmenge: 1

Preis: negotiate

Verpackung Informationen: Sperrholz/Holzpaket

Lieferzeit: 18 Tage

Zahlungsbedingungen: TT LC PayPal Kreditkarte

Beste Preis erhalten
Kontaktieren Sie uns jetzt
Spezifikationen
Hervorheben:

Laminar Flow Hood clean room equipment

,

Laminar Flow chamber air purification

,

Clean room air purifier 110V 220V

Stromspannung:
110V/220V 50HZ/60HZ
FFU-Größe:
1175*1175*320MM
Luftfluss:
Vertikal/horizontal
Filtereffizienz:
99,99%
Typ:
Hepa
Material:
Acryl/Aluminium
Luftvolumen:
1000 bis 1200 m3/h
Stromspannung:
110V/220V 50HZ/60HZ
FFU-Größe:
1175*1175*320MM
Luftfluss:
Vertikal/horizontal
Filtereffizienz:
99,99%
Typ:
Hepa
Material:
Acryl/Aluminium
Luftvolumen:
1000 bis 1200 m3/h
Beschreibung
Laminar Flow chamber Clean room Air Purification Equipment with 110V 220V voltage

Laminar Flow Hood Technology & Mycological Applications

I. Core Functionality & Classification

  1. Operating Principle
    Laminar flow hoods utilize HEPA filters (Grade H13/H14) to achieve 99.97%-99.995% retention efficiency for 0.3μm particles, creating ISO Class 5 clean zones. Two primary configurations exist:

  • Horizontal Laminar Flow Hoods: Parallel airflow to work surface, ideal for open operations

  • Vertical Laminar Flow Hoods: Downward airflow with protective front window

  1. Mycology-Specific Configurations
    Standard specifications include 24"x48" workstations and 12"x24"x5.8" filters. Selected models integrate UV sterilization (e.g., 27" wide desktop units). Portable designs enhance mobility, while stainless steel surfaces improve durability.

II. Critical Components & Technical Parameters

Component

Specifications

Application

HEPA Filter

5.8" thickness, fiberglass media

Spore containment

Blower Unit

EC brushless motor (0.3-0.5m/s)

Noise/energy optimization

Pre-filter

G4 grade

HEPA lifespan extension

Control System

Differential pressure alarm

Sterility maintenance

III. Mycological Cultivation Solutions

  1. Indoor Growth System Integration
    Laminar hoods can combine with Still Air Boxes for tiered protection:

  • Primary: Benchtop units with transparent covers

  • Advanced: FFU (Fan Filter Unit) clean rooms

  1. Maintenance Protocol

  • Filter replacement: 2000-3000 operating hours or ΔP≥250Pa

  • Routine care: 75% ethanol wipe-down + quarterly airflow verification

  • Upgrades: Optional VHP (Vaporized Hydrogen Peroxide) modules

IV. Selection Guidelines

  • Small-scale research: Horizontal desktop units with UV

  • Mass production: XL horizontal workstations

  • Mobile needs: Shock-resistant vertical flow hoods

Senden Sie Ihre Untersuchung
Bitte senden Sie uns Ihre Anfrage und wir werden Ihnen so schnell wie möglich antworten.
Senden